Diagnostics and maintenance
4.1 Diagnostics mechanisms of PROFINET IO
PROFINET with STEP 7 V15
86 Function Manual, 12/2017, A5E03444486-AH
Element of the data
structure
Designation according to
IEC 61158-6-10
Code
Data type /
length in bytes
AssetManagementBlock
(Structure depends on
the BlockType. Here it is
shown using
AM_FullInformation as
an example)
IM_UniqueIdentifier Manufacturer-generated Universal Unique
Identifier (UUID) conforming to ISO/IEC 9834-
8. Used as a reference key to uniquely identify
this asset.
Example: 550c5300-d34a-22b4-11d3-
5533991111
Array of Byte / 16
AM_Location Description of the location of the asset:
Either slot-oriented ("Slot and SubslotNumber
format") or hierarchical ("Twelve level tree
format").
See following description
Array of Byte / 16
IM_Annotation Manufacturer-specific notation
Example: "Terminal block, Type xyz123 ".
64 bytes are always used. Spaces are used
for padding if the string is shorter.
Array of Char /
64
IM_OrderID Manufacturer-specific article number
Example: "6ES7 131-6BF00-0BA0 ".
64 bytes are always used. Spaces are used
for padding if the string is shorter.
Array of Char /
64
AM_SoftwareRevision
(not at
AM_HardwareOnlyInformati
on)
Manufacturer-specific SW version
Example: "V6.3.8 ".
64 bytes are always used. Spaces are used
for padding if the string is shorter.
If the asset supports IM_Software_Revision,
the AM_SoftwareRevision is padded with
spaces.
Array of Char /
64
AM_HardwareRevision
(not at
AM_FirmwareOnlyInformati
on)
Manufacturer-specific hardware version
Example: "A4 ".
64 bytes are always used. Spaces are used
for padding if the string is shorter.
If the asset supports IM_Hardware_Revision,
the AM_HardwareRevision is padded with
spaces.
Array of Char /
64
IM_Serial_Number Manufacturer-specific unique production-
related number.
The characters come from the visible range
(0x20 ... 0x7E), no control characters.
Example: "A78C-1C82 ".
16 bytes are always used. Spaces are used
for padding if the string is shorter.
Array of Char /
16