OPC UA communication
9.3 Using the S7-1500 as an OPC UA server
Communication
Function Manual, 12/2017, A5E03735815-AF
199
Status "Bad" (8000_0000 - FFFF_FFFF)
Error code
(hex)
Name
Meaning
804D0000
BadBrowseDirectionInvalid
The browse direction is not valid.
804E0000
BadNodeNotInView
The node is not part of the view.
804F0000 BadServerUriInvalid The ServerUri is not a valid URI.
80500000
BadServerNameMissing
No ServerName was specified
80510000
BadDiscoveryUrlMissing
No DiscoveryUrl was specified.
80520000
BadSempahoreFileMissing
The semaphore file specified by the client is not valid.
80530000
BadRequestTypeInvalid
The security token request type is not valid.
80540000
BadSecurityModeRejected
The security mode does not meet the requirements set by the Server.
80550000
BadSecurityPolicyRejected
The security policy does not meet the requirements set by the Server.
80560000
BadTooManySessions
The server has reached its maximum number of sessions.
80570000
BadUserSignatureInvalid
The user token signature is missing or invalid.
80580000 BadApplicationSignature
Invalid
The signature generated with the client certificate is missing or invalid.
80590000 BadNoValidCertificates The client did not provide at least one software certificate that is valid and
meets the profile requirements for the server.
805A0000 BadRequestCancelled
ByRequest
The request was cancelled by the client with the Cancel service.
805B0000
BadParentNodeIdInvalid
The parent node id does not to refer to a valid node.
805C0000 BadReferenceNotAllowed The reference could not be created because it violates constraints imposed
by the data model.
805D0000 BadNodeIdRejected The requested node id was reject because it was either invalid or server
does not allow node ids to be specified by the client.
805E0000 BadNodeIdExists The requested node id is already used by another node.
805F0000
BadNodeClassInvalid
The node class is not valid.
80600000 BadBrowseNameInvalid The browse name is invalid.
80610000 BadBrowseNameDuplicated The browse name is not unique among nodes that share the same relation-
ship with the parent.
80620000
BadNodeAttributesInvalid
The node attributes are not valid for the node class.
80630000
BadTypeDefinitionInvalid
The type definition node id does not reference an appropriate type node.
80640000
BadSourceNodeIdInvalid
The source node id does not reference a valid node.
80650000
BadTargetNodeIdInvalid
The target node id does not reference a valid node.
80660000 BadDuplicateReference
NotAllowed
The reference type between the nodes is already defined.
80670000
BadInvalidSelfReference
The server does not allow this type of selfreference on this node.
80680000
BadReferenceLocalOnly
The reference type is not valid for a reference to a remote server.
80690000
BadNoDeleteRights
The server will not allow the node to be deleted.
806A0000
BadServerIndexInvalid
The server index is not valid.
806B0000
BadViewIdUnknown
The view id does not refer to a valid view node.
806D0000
BadTooManyMatches
The requested operation has too many matches to return.
806E0000
BadQueryTooComplex
The requested operation requires too many resources in the server.
806F0000
BadNoMatch
The requested operation has no match to return.
80700000
BadMaxAgeInvalid
The max age parameter is invalid.