OPC UA communication
9.3 Using the S7-1500 as an OPC UA server
Communication
202 Function Manual, 12/2017, A5E03735815-AF
Status "Bad" (8000_0000 - FFFF_FFFF)
Error code
(hex)
Name
Meaning
80C30000 BadFilterOperandCount
Mismatch
The number of operands provided for the filter operator was less than ex-
pected for the operand provided.
80C40000
BadFilterElementInvalid
The referenced element is not a valid element in the content filter.
80C50000
BadFilterLiteralInvalid
The referenced literal is not a valid value.
80C60000 BadIdentityChangeNotSup-
ported
The Server does not support changing the user identity assigned to the
session.
80C80000
BadNotTypeDefinition
The provided Nodeid was not a type definition nodeid.
80C90000
BadViewTimestampInvalid
The view timestamp is not available or not supported.
80CA0000
BadViewParameterMismatch
The view parameters are not consistent with each other.
80CB0000
BadViewVersionInvalid
The view version is not available or not supported.
80CC0000 BadConditionAlready
Enabled
This condition has already been enabled.
80CD0000
BadDialogNotActive
The dialog condition is not active.
80CE0000
BadDialogResponseInvalid
The response is not valid for the dialog.
80CF0000 BadConditionBranch
AlreadyAcked
The condition branch has already been acknowledged.
80D00000 BadConditionBranch
AlreadyConfirmed
The condition branch has already been confirmed.
80D10000 BadCondition-
AlreadyShelved
The condition has already been shelved.
80D20000
BadConditionNotShelved
The condition is not currently shelved.
80D30000 BadShelving-
TimeOutOfRange
The shelving time not within an acceptable range.
80D40000 BadAggregateListMismatch
The requested number of Aggregates does not match the requested number
of NodeIds.
80D50000
BadAggregateNotSupported
The requested Aggregate is not support by the server.
80D60000
BadAggregateInvalidInputs
The aggregate value could not be derived due to invalid data inputs.
80DB0000 BadTooManyMonitoredItems The request could not be processed because there are too many monitored
items in the subscription.
80D70000
BadBoundNotFound
No data found to provide upper or lower bound value.
80D80000
BadBoundNotSupported
The server cannot retrieve a bound for the variable.
80DA0000 BadAggregateConfiguration
Rejected
The aggregate configuration is not valid for specified node.
80E10000 BadDominantValueChanged The related EngineeringUnit has been changed but this change has not
been applied to the device. The Variable Value is still dependent on the
previous unit but its status is currently bad.
80E30000 BadDependentValue-
Changed
A dependent value has been changed but the change has not been applied
to the device. The quality of the dominant variable is bad.
80E40000 BadRequestNotAllowed The request was rejected by the server because it did not meet the criteria
set by the server.
80E50000
BadTooManyArguments
Too many arguments were provided.
80E60000
BadSecurityModeInsufficient
The operation is not permitted over the current secure channel.
810D0000 BadCertificateChainIncom-
plete
The certificate chain is incomplete.