OPC UA communication
9.3 Using the S7-1500 as an OPC UA server
Communication
Function Manual, 12/2017, A5E03735815-AF
201
Status "Bad" (8000_0000 - FFFF_FFFF)
Error code
(hex)
Name
Meaning
808E0000
BadDeadbandFilterInvalid
The dead band filter is not valid.
80970000 BadRefreshInProgress This Condition refresh failed, a Condition refresh operation is already in
progress.
80980000 BadConditionAlreadyDisa-
bled
This condition has already been disabled.
80990000
BadConditionDisabled
Property not available, this condition is disabled.
809A0000
BadEventIdUnknown
The specified event id is not recognized.
809B0000
BadNoData
No data exists for the requested time range or event filter.
809D0000
BadDataLost
Data is missing due to collection started/stopped/lost.
809E0000 BadDataUnavailable Expected data is unavailable for the requested time range due to an un-
mounted volume an off-line archive or tape or similar reason for temporary
unavailability.
809F0000 BadEntryExists The data or event was not successfully inserted because a matching entry
exists.
80A00000 BadNoEntryExists The data or event was not successfully updated because no matching entry
exists.
80A10000 BadTimestampNotSupported The client requested history using a timestamp format the server does not
support (i. e. requested ServerTimestamp when server only supports
SourceTimestamp).
80AB0000
BadInvalidArgument
One or more arguments are invalid.
80AC0000
BadConnectionRejected
Could not establish a network connection to remote server.
80AD0000
BadDisconnect
The server has disconnected from the client.
80AE0000
BadConnectionClosed
The network connection has been closed.
80AF0000 BadInvalidState The operation cannot be completed because the object is closed uninitial-
ized or in some other invalid state.
80B00000
BadEndOfStream
Cannot move beyond end of the stream.
80B10000
BadNoDataAvailable
No data is currently available for reading from a non-blocking stream.
80B20000
BadWaitingForResponse
The asynchronous operation is waiting for a response.
80B30000
BadOperationAbandoned
The asynchronous operation was abandoned by the caller.
80B40000 BadExpectedStreamToBlock The stream did not return all data requested (possibly because it is a non-
blocking stream).
80B50000
BadWouldBlock
Non-blocking behavior is required and the operation would block.
80B60000
BadSyntaxError
A value had an invalid syntax.
80B70000 BadMaxConnections
Reached
The operation could not be finished because all available connections are in
use.
80BB0000 BadEventNot
Acknowledgeable
The event cannot be acknowledged.
80BD0000 BadInvalidTimestamp
Argument
The defined timestamp to return was invalid.
80BE0000 BadProtocolVersion
Unsupported
The applications do not have compatible protocol versions.
80C10000
BadFilterOperatorInvalid
An unrecognized operator was provided in a filter.
80C20000 BadFilterOperator
Unsupported
A valid operator was provided, but the server does not provide support for
this filter operator.