Modes and Jobs
9-21
FM 351 Positioning Module
C79000-G7076-C351-02
Address CommentInitial ValueTypeName
36.2 TRG252_254_EN BOOL FALSE 1 = write incremental dimension for
incremental dimension number 254
36.3 TRG255_EN BOOL FALSE 1 = write incremental dimension for
incremental dimension number 255
35.4 TRGL1WR_EN BOOL FALSE 1 = write incremental dimension table 1
(incremental dimension number 1 ... 50)
35.5 TRGL2WR_EN BOOL FALSE 1 = write incremental dimension table 2
(incremental dimension number 51 ... 100)
96.0 TRG252_254 DINT L#0 Incremental dimension for incremental
dimension number 254
100.0 TRG255 DINT L#0 Incremental dimension for incremental
dimension number 255
104.0 CHGDIF_255 DINT L#0 Switchover difference for incremental
dimension number 255
108.0 CUTDIF_255 DINT L#0 Switch-off difference for incremental
dimension number 255
Data Used in the Parameter DB
Address Name Type Initial Value Comment
100.0 CHGDIF_P DINT L#5000 Switchover difference plus
104.0 CHGDIF_M DINT L#5000 Switchover difference minus:
108.0 CUTDIF_P DINT L#2000 Switch-off difference plus
112.0 CUTDIF_M DINT L#2000 Switch-off difference minus
120.0 TRGL1.TRG[1] DINT L#0 Incremental dimension number 1
.
.
.
.
.
.
.
.
Incr. dim. table 1
316.0 TRGL1.TRG[50] DINT L#0
Incremental dimension number 50
320.0 TRGL2.TRG[51] DINT L#0 Incremental dimension number 51
.
.
.
.
.
.
.
.
Incr. dim. table 2
516.0 TRGL2.TRG[100] DINT L#0
Incremental dimension number 100