Programming the FM 351
6-14
FM 351 Positioning Module
C79000-G7076-C351-02
6.5.3 Diagnostic DB
Task
The diagnostic DB (see Appendix C.3, page C-11) contains the data for FC
ABS_DIAG and also contains the diagnostic buffer of the module created by this
function.
Structure
Diagnostic DB
Internal data
Job status
Trigger bit
Diagnostic buffer
Module address
6.5.4 Parameter DB
Task
If you want to modify the machine data and incremental dimension tables during
operation, you require a parameter DB (see Appendix C.2, page C-9) in which
these data are stored. The parameters can be modified by the user program or by
an operator control and monitoring system.
You can export the data displayed in the configuration software to a parameter DB.
You can also import a parameter DB into the configuration software and display it
there.
There can be several sets of parameter data for each channel (for example for
different recipes) the required set being selected in the program.
Structure
Parameter DB
Machine data
Incremental dimension tables