Programming the FM 351
6-20
FM 351 Positioning Module
C79000-G7076-C351-02
Typical Situations for the Transfer of Parameters:
You edit the parameters with the configuration software. You then want the channels
of the module to have parameters assigned automatically during startup.
Action required: steps 1, 2 and 2a.
You modify the parameters during commissioning in the test mode in the configuration
software: Action required: steps 4 and 5.
You want the parameters modified during commissioning to be loaded automatically
during startup:
Action required: steps 1, 2 and 2a.
You create the parameters with the configuration software. You want the channels of
the module to be assigned parameters during startup only by the user program using
data blocks:
Action required: steps 10, 10a and 6 or 10b and 6.
You want to create data for recipes::
Action required: steps 10 and 10a.
You create the parameters with the configuration software. These should be available
to the user program for temporary modifications.
Action required: steps 1, 2 and 2a for automatic parameter assignment.
Action required: steps 10, 10a, 9, 8 and 6 for access by the user program.
You modify existing parameters (exclusively) with the user program:
Action required: steps 7, 9, 8 and 6.
You want to view the data modified by the user program in the configuration software:
Action required: steps 11a and 11 or only 11b.
The parameters modified by the user program should be downloaded automatically
during startup:
Action required: steps 11b or 11a, 11 and then 1, 2, 2a.