Loading...
Machine Data and Incremental Dimensions
8-26
FM 351 Positioning Module
C79000-G7076-C351-02
Data Used in the Parameter DB
Address Name Type Initial Value Comment
100.0 CHGDIF_P DINT L#5000 Switchover difference plus
104.0 CHGDIF_M DINT L#5000 Switchover difference minus:
108.0 CUTDIF_P DINT L#2000 Switch-off difference plus
112.0 CUTDIF_M DINT L#2000 Switch-off difference minus
8.8.3 Incremental Dimension Number 255
Incremental dimension number 255 also allows you to set the distance.
You transfer the switch-off differences and the switchover differences together with
the incremental dimension. In contrast to the other incremental dimensions,
incremental dimension 255 uses the value for the switch-off and switchover
difference specified in the channel DB. The entries from the machine data have no
validity for this incremental dimension.
Data Used in the Channel DB
Address Name Type Initial Value Comment
36.3 TRG255_EN BOOL FALSE 1 = write incremental dimension for
incremental dimension number 255
100.0 TRG255 DINT L#0 Incremental dimension for incremental
dimension number 255
104.0 CHGDIF255 DINT L#0 Switchover differences for incremental
dimension number 255
108.0 CUTDIF255 DINT L#0 Switch-off differences for incremental
dimension number 255