2.3 Differentiation from other program blocks
Ident profile and Ident blocks, standard function for Ident systems
Function Manual, 10/2018, C79000-G8976-C387-04
11
2.3
Differentiation from other program blocks
Functions supported by program blocks
The following table provides an overview of the functions supported by the program blocks.
Table 2- 4 Supported functions of the program blocks
Program
block
Functions supported by program block
Singletag
Multitag
Normal ad-
dressing
File
handler
PROFIBUS
PROFINET
MV
Ident profile
-- Block based on the
PNO specification
(Based on the stand-
ard profile V1.19, how-
ever without file
handler)
Ident blocks
-- Blocks based on the
Ident profile
Standard
profile V1.19
Recommended block
for third-party control-
lers
FB 45
-- -- Block for single tag
applications
FB 55
-- -- Block for multitag ap-
plications
FC 56
-- -- -- Recommended block
for file handler
FC 44
--
--
--
--
Only for RF160C
Application
blocks
RF160C
-- -- -- -- Only for RF160C
Application
blocks
IO-Link
-- -- -- Only for RF200 IO-Link