Setting parameters for blocks
3.4 Programming Ident blocks
Ident profile and Ident blocks, standard function for Ident systems
54 Function Manual, 10/2018, C79000-G8976-C387-04
3.4.3.4
Reset_RF200
Figure 3-26 "Reset_RF200" block
Table 3- 31 Explanation of the "Reset_RF200" block
Parameter
Data type
Default values
Description
TAG_CONTROL Byte 1 Presence check
TAG_TYPE Byte 1 Transponder type:
1 = every ISO transponder
3 = MDS D3xx - optimization
RF_POWER Byte 4 Output power; only relevant for
RF290R
RF power from 0.5 W to 5 W in incre-
ments of 0.25 W (range of values:
0x02 ... 0x14).
Default value 0x04 1 W.