Setting parameters for blocks
3.4 Programming Ident blocks
Ident profile and Ident blocks, standard function for Ident systems
64 Function Manual, 10/2018, C79000-G8976-C387-04
3.4.4.2
Tag_Status
The "Tag_Status" block reads the status information of the transponder. For the various
transponder types and reader families, there are different status modes that you can select
using the "ATTRIBUTE" parameter.
Figure 3-31 "Tag_Status" block
Table 3- 45 Explanation of the "Tag_Status" block
Parameter
Data type
Default values
Description
ATTRIBUTE Byte B#16#0 Identifier of the status modes / possi-
ble entries:
RF200: 0x83
RF300: 0x04, 0x82, 0x83
1)
RF620R, RF630R: 0x84, 0x85
MOBY D: 0x83
2)
MOBY U: 0x80
LEN_ID Byte B#16#0 Length of the EPC-ID/UID
Default value: 0x00 ≙ unspecified
single tag access (RF61xR, RF68xR)