Setting parameters for blocks
3.4 Programming Ident blocks
Ident profile and Ident blocks, standard function for Ident systems
56 Function Manual, 10/2018, C79000-G8976-C387-04
Figure 3-28 "Reset_RF600" block
Table 3- 33 Explanation of the "Reset_RF600" block (RF620R/RF630R)
RADIO_PROFILE Byte 1 Scanning time: Wireless profile ac-
cording to EPC Global
(range of values: 0x01 ... 0x09 de-
pending on the reader variant)
POWER_ANT1 Byte 0 Transmit power for antenna 1 or inter-
nal antenna
(range of values: 0x00 ... 0x0F)
POWER_ANT2 Byte 0 Transmit power for antenna 2 or ex-
ternal antenna
(range of values: 0x00 ... 0x0F)
UID_HANDLE Bool False Meaning of the UID in the command:
True = Handle ID, only the least signif-
icant 4 bytes of the UID are evaluated;
False = UID/EPC-ID with a length of 8
True = activate black list