Appendix
A.2 Cyclic data
Ident profile and Ident blocks, standard function for Ident systems
136 Function Manual, 10/2018, C79000-G8976-C387-04
The following table shows the codes of the cyclic status word.
Table A- 5 Codes of the status word: Cyclic input data
UIN0 ... UIN3 With RFID readers, the number of
transponders in the antenna field is
indicated. UIN0 ... UIN3 can be
interpreted as binary values.
Example:
UIN3 = 0; UIN2 = 0; UIN1 = 1; UIN0
= 1
⇒ 3 transponders
With optical reader devices, the
various states of the reader are
displayed.
• UIN0: Corresponds to "IN_OP"
bit of the reader
• UIN1: Corresponds to "RDY" bit
of the reader
• UIN2 + UIN3: These two bits are
interpreted as an unsigned value
(bit 2 is the less significant bit)
that represents the number of
available decoded codes. If the
value = 3, three or more decoded
codes are available.
ERR_IREQ 1 = An error has occurred on the communications module or reader (e.g.
on start-up of the reader, connection termination or with RF61xR, RF68xR
SRESETACT 1= Indicates that the command currently being processed within the read-
er/optical reader has been aborted. The bit is reset to "0" after "SRESET"