Setting parameters for blocks
3.4 Programming Ident blocks
Ident profile and Ident blocks, standard function for Ident systems
52 Function Manual, 10/2018, C79000-G8976-C387-04
3.4.3.2
Reset_MOBY_U
Figure 3-24 "Reset_MOBY_U" block
Table 3- 29 Explanation of the "Reset_MOBY_U" block
Parameter
Data type
Default values
Description
TAG_CONTROL
Bool
True
Presence check
DISTANCE Byte 23h Range limitation
(range of values: 0x02 ... 0x23 or 0x82
... 0xA3 for reduced transmit power)
MULTITAG Byte 1 Maximum number of transponders
that can be processed at the same
time in the antenna field.
(Range of values: 0x01 ... 0x12)
SCAN_TIME Byte 0 Scanning time: Standby time of the
transponder
(range of values: 0x00 ... 0xC8)
FCON Byte 0 field_ON_control: BERO mode
(range of values: 0x00 ... 0x03)
FTIM Byte 0 field_ON_time: Time for BERO mode
(range of values: 0x00 ... 0xFF)