Setting parameters for blocks
3.4 Programming Ident blocks
Ident profile and Ident blocks, standard function for Ident systems
Function Manual, 10/2018, C79000-G8976-C387-04
27
3.4.1.4
Set_MV_Program
With the aid of the "Set_MV_Program" block, you can change the program in a camera. The
required program number is transferred using the "PROGRAM" parameter.
Figure 3-8 "Set_MV_Program" block
Table 3- 6 Explanation of the "Set_MV_Program" block
Parameter
Data type
Default values
Description
PROGRAM Byte B#16#1 Program number
Range of values: 0x01 ... 0x0F
3.4.1.5
Write
The "Write" block writes the user data from the "IDENT_DATA" buffer to the transponder.
The physical address and the length of the data are transferred using the "ADDR_TAG" and
"LEN_DATA" parameters. With the RF61xR/RF68xR readers, the block writes the data to
memory bank 3 (USER area). Specific access to a certain transponder takes place with the
optional "EPCID_UID" and "LEN_ID" parameters.
Figure 3-9 "Write" block