Setting parameters for blocks
3.4 Programming Ident blocks
Ident profile and Ident blocks, standard function for Ident systems
28 Function Manual, 10/2018, C79000-G8976-C387-04
Table 3- 7 Explanation of the "Write" block
Parameter
Data type
Default values
Description
ADDR_TAG DWord DW#16#0 Physical address on the transponder
where the write starts. You will find
more information on addressing in the
section "Transponder addressing
(Page 113)".
With MV: Address is always 0.
1)
LEN_DATA
Word
W#16#0
Length of the data to be written
LEN_ID Byte B#16#0 Length of the EPC-ID/UID
Default value: 0x00 ≙ unspecified
single tag access (RF200, RF300,
RF61xR, RF68xR)
EPCID_UID Array[1...62] of
Byte
0 Buffer for up to 62 bytes EPC-ID, 8
bytes UID or 4 bytes handle ID.
2 - 62-byte EPC-ID is entered at
the start of the buffer (length is set
by "LEN_ID")
8-byte UID is entered at the start
of the buffer ("LEN_ID = 8")
4-byte handle ID must be entered
in the array element [5]-[8]
("LEN_ID = 8")
Default value: 0x00 ≙ unspecified
single tag access (RF620R, RF630R)
IDENT_DATA Any / Variant 0 Data buffer with the data to be written.
With MV: The first byte encodes the
corresponding MV command.
1)
Note:
For Variant, currently only an "Ar-
ray_of_Byte" with a variable length
can be created. For Any, other data
types/UDTs can also be created.
1)
You can find additional information on working with optical reader systems in the operating instruc-
tions for "SIMATIC MV420 / SIMATIC MV440" and "SIMATIC MV500".