Setting parameters for blocks
3.4 Programming Ident blocks
Ident profile and Ident blocks, standard function for Ident systems
Function Manual, 10/2018, C79000-G8976-C387-04
53
3.4.3.3
Reset_MV
To reset cameras of the optical reader systems, call the block and activate the "EXECUTE"
parameter.
Figure 3-25 "Reset_MV" block
Table 3- 30 Explanation of the "Reset_MV" block
Parameter
Data type
Description
PROGRAM Byte Program selection
B#16#0: Reset without program selection or
in the case of diagnostics, the error code for
"IN_OP = 0" is shown at the "STATUS" out-
put parameter.
B#16#1 ... B#16#0F: Number of the program
to be started
⇒ Reset with program selection (as of firm-
ware V5.1 of the MV4x0)