Setting parameters for blocks
3.4 Programming Ident blocks
Ident profile and Ident blocks, standard function for Ident systems
Function Manual, 10/2018, C79000-G8976-C387-04
45
3.4.2.7
Set_Param
With the "Set_Param" block, you can change UHF parameters on an
RF18xC/RF61xR/RF68xR during runtime (e.g. the antenna power).
Note
Settings saved only temporarily
Note that the parameters in the "Set_Param" block are only stored temporarily. If the power
for the reader is interrupted, the stored values are lost and must be set again.
Figure 3-19 "Set_Param" block
Table 3- 23 Explanation of the "Set_Param" block
Parameter
Data type
Default values
Description
PARMID
DWORD
0x00
Parameter identifier
VALUE
DWORD
0x00
Parameter value