Setting parameters for blocks
3.4 Programming Ident blocks
Ident profile and Ident blocks, standard function for Ident systems
Function Manual, 10/2018, C79000-G8976-C387-04
47
PARMID
(hex)
PARMID
(ASCII)
Parameter
VALUE
0x52364353 R6CS Modulation scheme Range of values: 32, 33, 34, 35, 37,
65
Modulation scheme of the read
point
Specification of which transponder
types are identified (ISO 18000-63/-
62).
32: Tx: 40 Kbps / Rx: 40 Kbps /
FM0
33: Tx: 40 Kbps / Rx: 62:5 Kbps
/ Miller4
34: Tx: 40 Kbps / Rx: 75 Kbps /
Miller4
35: Tx: 80 Kbps / Rx: 62:5 Kbps
/ Miller4
37: Tx: 80 Kbps / Rx: 400 Kbps
/ FM0
65: Tx: 40 Kbps / Rx: 40 Kbps /
ISO 18000-62
0x57544348 WTCH Date and time Range of values: 01.01.2000 00:00
a.m. ... 19.01.2038 3:14 a.m.
01.01.2000 01:00 a.m.
946684800
Date and time (UTC)
Time in seconds since 01/01/1970;
Setting of the internal reader/CM
clock, whereby the date and time
are set.
0x57544F44 WTOD Time Range of values: 0:00 23:59 p.m.
S7 time (TOD, UTC)
Milliseconds since midnight;
Setting of the internal reader/CM
clock, whereby only the time is
changed but not the date.
0x57444154 WDAT Date Range of values:
01.01.2000 ... 18.01.2038
S7 date
Days since 01/01/1990;
Setting of the internal reader/CM
clock, whereby only the date is
changed and not the time.