Configuring firmware
3.4 "Advanced" tab
Firmware/BIOS description (SIMATIC IPC BX-56A, IPC BX-59A)
Operating Instructions, 10/2023, A5E52427534-AA
15
3.4.7 "Fan Control"
Calling "Fan Control"
Select: "Setup Utility (Page 10)" > "Advanced" > "Fan Control".
Firmware
setting
Value Setting in
delivery state
Meaning
BX-56A
BX-59A
FAN1
Fan Control
Mode
Auto
x
x
Choose control mode.
Max
FAN2
Fan Control
Mode
Auto
x
x
Choose control mode.
Max
3.4.8 "Miscellaneous Configuration"
Calling "Miscellaneous Configuration"
Select: "Setup Utility (Page 10)" > "Advanced" > "Miscellaneous Configuration".
Firmware
setting
Value Setting in
delivery state
Meaning
BX-56A
BX-59A
HPET - HPET
Support
Enabled
x
x
The HPET (High Precision Event Timer) can be used by operating
system.
Disabled
The HPET cannot be used by operating system.
State After
power failure
S0 State
x
x
After voltage failure and subsequent voltage restoration, the
device switches on automatically.
S5 State
After voltage failure and subsequent voltage restoration, the
device remains switched off.
Last State
If the device is switched on when the power fails, the device will
switch back on when the power returns. Otherwise, the device
remains switched off.
HD Audio
Enabled
x
x
The onboard HD (High Definition) Audio Controller is enabled.
Disabled
The onboard HD Audio Controller is disabled.