Technical specifications
8.4 Technical data
SIMATIC IPC377G
76 Operating Instructions, 07/2022, A5E51366314-AB
1139 to 700 hPa, corresponds to an altitude of -1000
to 3000 m
1139 to 660 hPa, corresponds to an altitude of -1000
to 3500 m
Multiplication factors for equipment ambient temperature of operation at altitudes up to
3000m, tested in accordance with IEC 61131-2:2017
Derating ratio for temperature
1
2
: Equipment ambient temperature rating at 2000 m.
: Atmospheric pressure and air density increases with decreasing altitude. Therefore, utilization of
the derating factor for 0 m to 2000 m for altitudes below sea level is considered conservative.
Mechanical ambient conditions
Vibration resistance, tested in accordance with IEC 60068-2-6
• 5 to 8.4 Hz: 3.5 mm
• 8.4 to 500 Hz: 9.8 m/s²
Storage/transport
• 5 to 8.4 Hz: 3.5 mm
• 8.4 to 500 Hz: 9.8 m/s
2
Shock resistance, tested in accordance with IEC 60068-2-27
• 150 m/s², 11 ms
• 5g, 30 ms
• 250 m/s
2
, 6 ms
8.4.3 Power demand of the components
Maximum power consumption of the auxiliary components
Auxiliary components Maximum permitted
Max. total power
6 W (for all USB devices)
M.2 Module (slot
Per slot -- 1.5 A 5 W in total