Technical information
8.4 Technical specifications
SIMATIC IPC477D, IPC477D PRO
Operating Instructions, 11/2016, A5E31347228-AF
215
Note
Ambient temperature with DVD operation
For a device with DVD drive for drive operation:
Reading up to max. 40 °C ambient temperature at the device
Writing up to max. 35 °C ambient temperature at the device
Relative humidity, tested in accordance with IEC 60068-2-78, IEC 60068-2-30
Operation
5 ... 85% at 30 °C, no condensation
Storage/transport
5 to 95 % at 25/55 °C, no condensation
Air pressure, in accordance with IEC 60068-2-13
Operation
1080 hPa to 795 hPa, corresponds to an elevation of 1000 m to 2000 m
Storage/transport
1080 hPa to 660 hPa, corresponds to an elevation of 1000 m to 3500 m
Protection against foreign objects and water
Degree of protection
Explanation
Front When mounted:
IP65 according to IEC 60529
Front face only Type 4X/Type 12 (indoor use only) according to
UL50
Rear panel IP20
Touch protection test with standard test probes. There is no protection
against ingress by water.
The degree of protection of the device front can only be guaranteed if the mounting seal is
intact and lies flush against the mounting cutout.

Table of Contents

Other manuals for Siemens SIMATIC IPC477D

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC IPC477D and is the answer not in the manual?

Siemens SIMATIC IPC477D Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC IPC477D
CategoryIndustrial PC
LanguageEnglish

Related product manuals