5.4.5 Technical specifications
Table 5- 32 Technical specifications of the RF680R reader
6GT2811-6AA10-xAA0
Product type designation
SIMATIC RF680R
Radio frequencies
Operating frequency
• ETSI • 865 to 868 MHz
• FCC • 902 to 928 MHz
• CMIIT • 920 to 925 MHz
• ARIB (STD-T106) • 916.8 MHz to 920.4 MHz
Transmit power
1)
• ETSI • 3 to 2000 mW
• FCC • 3 to 2000 mW
• CMIIT • 3 to 2000 mW
• ARIB (STD-T106) • 3 to 1000 mW
Maximum radiated power per antenna
• ETSI • 2000 mW ERP
• FCC • 4000 mW EIRP
• CMIIT • 2000 mW ERP
• ARIB (STD-T106) • 4000 mW EIRP
Electrical data
Range
• ETSI • ≤ 8 m
• FCC • ≤ 8 m
• CMIIT • ≤ 8 m
• ARIB (STD-T106) • ≤ 8 m
Protocol
ISO 18000-62/-63
Transmission speed
≤ 300 kbps
Frequency accuracy
≤ ±10 ppm