Transponder
7.14 SIMATIC RF680T
SIMATIC RF600
436 System Manual, 11/2018, J31069-D0171-U001-A21-7618
7.14.4 Technical specifications
Table 7- 56 Technical specifications of the transponder SIMATIC RF680T
6GT2810-2HG80
Product type designation
SIMATIC RF680T
Radio frequencies
Operating frequency
• ETSI • 865 to 868 MHz
• FCC • 902 ... 928 MHz
1)
Memory
Chip (manufacturer/type)
NXP / G2XM
Memory type
EEPROM
Memory configuration
• EPC • 12 ... 30 bytes / 96 ... 240 bits
• User memory • 64 bytes / 512 bits
• TID • 8 bytes / 64 bits
• Reserved (passwords) • 8 bytes / 64 bits
Number of write cycles (< 40 °C)
> 10
14
Number of read cycles (< 40 °C)
> 10
5
Data retention time (< 40 °C)
10 years
Electrical data
Range
≤ 5 m
2)
Protocol
ISO 18000-63
Transmission speed
≤ 320 kbps
Polarization
Linear
Mechanical specifications
Material
PPS
Silicone-free
Yes
Color Black
Printing No