Antennas
6.5 SIMATIC RF642A
SIMATIC RF600
System Manual, 11/2018, J31069-D0171-U001-A21-7618
281
Plug connection 30 cm coaxial cable with RP-TNC coupling
(for connection of the antenna cable)
Mechanical specifications
Tightening torque (at room temperature)
Permitted ambient conditions
• During operation • -25 ... +75 °C
• During transportation and storage • -40 ... +85 °C
Shock resistant to EN 60068-2-27
2)
Vibrations according to EN 60068-2-6
2)
Design, dimensions and weight
Standards, specifications, approvals
Proof of suitability CE (according to RED), FCC (Title 47, Part
15.247), cULus
The values differ for different dimensions/materials of the mounting surface.
2)
The values for shock and vibration are maximum values and must not be applied continuously.