Transponder
7.7 SIMATIC RF610T ATEX
SIMATIC RF600
System Manual, 11/2018, J31069-D0171-U001-A21-7618
379
Permitted ambient conditions
• In operation, during write/read access • -25 ... +85 °C
• In operation, outside write/read access • -40 ... +85 °C
• During transportation and storage • -40 … +85 °C
Not suitable for mounting directly on metal
Resistance to mechanical stress Torsion and bending stress conditionally permis-
Shock-resistant according to DIN EN 60721-3-7,
100 g
2)
Vibration to EN 60068-2-6
2)
Design, dimensions and weight
Standards, specifications, approvals
Proof of suitability TÜV 11 ATEX 081778 X
(EN 60079-0, EN 60079-11):
II 3 G Ex ic IIB T6/T5/T4 Gc,
II 3 D Ex ic IIIB T
5
120°C Dc,
1)
The information relates to the maximum read range. You will find more information on
ranges in the section "Minimum distances and maximum ranges (Page 337)".
2)
The values for shock and vibration are maximum values and must not be applied
continuously.
Note
Effects of temperatures > 70 °C
Note that in
temperature ranges > 70 °C, the transponder can become slightly deformed.
However, this has no effect on the transponder function.