Device maintenance and repair
7.3 Manage onboard RAID system
SIMATIC IPC547G
Operating Instructions, 04/2020, A5E49948632-AA
111
Manual integration of the hard disk (in the event of an error)
1. Select "Start" > "Programs" > "Intel Rapid Storage Technology".
2. Click
"Run Hardware Scan now".
The new hard disk is found and displayed.
Click on the link "Rebuild to another Disk".
Or:
1. Reboot the device.
The RAID software automatically integrates the hard disk.
2. Click on the link "Rebuild to another Disk".
Synchronization of the RAID system is initiated after clicking the link "Rebuild to another
disk".