Device maintenance and repair
7.4 Removing and installing hardware
SIMATIC IPC547G
126 Operating Instructions, 04/2020, A5E49948632-AA
7.4.8 Replace the adapter module for the removable tray
Requirement
The device is equipped with the drive cage type A.
The device is fully disconnected from the mains voltage; see section "Switching off the
device (Page 63)".
The device is open; see section "Open the device (Page 76)".
All slot covers and removable trays have been removed.
Procedure
Removal
1. Note the assignment of all SATA cables and detach all the SATA cables .
2. Unlatch the adapter module for the removable rack unit by firmly pressing on the latches
in the direction of the arrow and pressing on the ejector .
3. Loosen the unlatched adapter module
by rotating it upwards from the brackets and
take it out of the drive cage.
Installation
1. Insert the new adapter module for removable rack unit into the drive bay from the front
and snap it into place at the back, see section "Installing a hard disk drive or SSD in slot 0
to 2 (Page 89)".

Table of Contents

Other manuals for Siemens Simatic series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens Simatic series and is the answer not in the manual?

Siemens Simatic series Specifications

General IconGeneral
ProcessorIntel Core i3, Core i5, Core i7
Operating SystemWindows 10 IoT Enterprise, Linux
StorageSSD, HDD
InterfacesEthernet, USB, RS-232/485
PortsEthernet, USB, Serial
MountingDIN rail, wall
Protection ClassIP65
GraphicsIntegrated Intel HD Graphics
Expansion SlotsPCIe
Power Supply24V DC or 100-240V AC
Operating Temperature0°C to 50°C (depending on model)

Related product manuals