Getting Started
24 A5E37208904-003, 04/2017
Specific technical data
SINAMICS V90 PN 200V variant
Max. supported motor power (kW)
Power sup-
ply
Voltage/frequency FSB and FSC: single phase/three phase 200 VAC to 240 VAC, 50/60 Hz
FSD: three phase 200 VAC to 240 VAC, 50/60 Hz
-15% to +10%
Permissible frequency
-10% to +10%
Permissible supply con-
TN, TT, IT
Rated input
current (A)
3-phase 1.5 1.8 3.0 5.0 7.0 11.0 12.0
Power supply
capacity
3-phase 0.5 0.7 1.1 1.9 2.7 4.2 4.6
1)
The values here are calculated at rated load.
SINAMICS V90 PN 400V variant
Max. supported motor power (kW)
17 57 57 131 131 339 339 339
Output frequency (Hz) 0 to 330