Getting Started
A5E37208904-003, 04/2017
83
The section below lists all the parameters of the SINAMICS V90 PN servo drive.
Numbers prefixed with an "r" indicate that parameter is a read-only parameter.
Numbers prefixed with a "p" indicate that the parameter is an editable parameter.
Indicates the conditions for making parameterization effective. Two conditions are possible:
● IM (
mediately): Parameter value becomes effective immediately after changing.
● RE (
set): Parameter value becomes effective after repower-on.
This indicates when the parameter can be changed. Two states are possible:
●
(Run): Can be changed in the "
" state when the drive is in "servo on" state. The "RDY" LED lights up green.
●
(Ready to run): Can be changed in the "
" state when the drive is in "servo off" state. The "RDY" LED lights up
red.
Note
When judging the state of the drive according to the "RDY" LED, ensure that no faults or alarms exist.
FloatingPoint32 Float 32-bit floating point number
The SINAMICS V90 PN parameters are divided into the following groups:
Parameter group display on
the BOP
Basic parameters p07xx, p10xx to p16xx, p21xx
Application parameters p29xxx
Communication parameters p09xx, p89xx
Basic positioner parameters p25xx, p26xx
Status monitoring parameters All read-only parameters