Getting Started
A5E37208904-003, 04/2017
73
Signal
Description
STW1.6 1 = Enable setpoint
0 = Inhibit setpoint (set the ramp-function generator input to zero)
STW1.7
= 1. Acknowledge faults
STW1.8
Reserved
STW1.9
Reserved
STW1.10
1 = Control via PLC
STW1.11
1 = Ramp-function generator active
STW1.12
1 = Unconditionally open the holding brake
STW1.13 Reserved
STW1.14
Reserved
STW1.15 Reserved
6.3.4
STW2 control word (for telegrams 102, 105)
Note
When p29108.0 = 0, STW2.4 is disabled.
Signal
Description
STW2.0
Reserved
STW2.1
Reserved
STW2.2 Reserved
STW2.3
Reserved
STW2.4
1 = Bypass ramp-function generator
STW2.5
Reserved
STW2.6
1 = Integrator inhibit, speed controller
STW2.7
Reserved
STW2.8
1 = Traverse to fixed endstop
STW2.9
Reserved
STW2.10
Reserved
STW2.11
Reserved
STW2.12
Master sign-of-life, bit 0
STW2.13
Master sign-of-life, bit 1
STW2.14
Master sign-of-life, bit 2
STW2.15
Master sign-of-life, bit 3