Specific technical data
SIMOTICS S-1FL6, low inertia servo motor
Article No.
1FL60...
22
24
32
34
42
44
52
54
Rated power [kW]
0.05
0.1
0.2
0.4
0.75
1
1.5
2
Rated torque [Nm]
0.16
0.32
0.64
1.27
2.39
3.18
4.78
6.37
Maximum torque [Nm]
0.48
0.96
1.91
3.82
7.2
9.54
14.3
19.1
Rated speed [rpm]
3000
Maximum speed [rpm]
5000
Rated frequency [Hz]
200
Rated current [A] 1.2 1.2 1.4 2.6 4.7 6.3 10.6 11.6
Maximum current [A]
3.6
3.6
4.2
7.8
14.2
18.9
31.8
34.8
Moment of inertia [10
-4
kgm
2
]
0.031 0.052 0.214 0.351 0.897 1.15 2.04 2.62
Moment of inertia (with
brake) [10
-4
kgm
2
]
0.038 0.059 0.245 0.381 1.06 1.31 2.24 2.82
Recommended load to mo-
tor inertia ratio
Max. 30x Max. 20x Max. 15x
Operating temperature [°C] 1FL602❑, 1FL603❑ and 1FL604❑: 0 to 40 (without power derating)
1FL605❑: 0 to 30 (without power derating)
1)
Storage temperature [°C]
-20 to +65
Maximum noise level [dB]
60
Holding
brake
Rated voltage
(V)
24 ± 10%
Rated current
(A)
0.25 0.3 0.35 0.57
Holding brake
torque [Nm]
0.32 1.27 3.18 6.37
Maximum
brake opening
time [ms]
35 75 105 90
Maximum
brake closing
time [ms]
10 10 15 35
Maximum
number of
emergency
stops
2000
2)
Oil seal lifetime [h]
3000 to 5000
Encoder lifetime [h]
> 20000
3)
Protection degree of motor
body
IP 65
Protection degree of cable
end connector
IP20 -
Weight [kg]
With brake
0.70
0.86
1.48
1.92
3.68
4.20
6.76
8.00
Without brake
0.47
0.63
1.02
1.46
2.80
3.39
5.35
6.56
1)
When the surrounding temperature is between 30 °C and 40 °C, the 1FL605 motor will have a power derating of 10%.
2)
Restricted emergency stop operation is permissible. Up to 2000 braking operations for the motors of 0.05 kW to 1 kW,
and 200 braking operations for the motors of 1.5 kW to 2 kW can be executed with 300% rotor moment of inertia as ex-
ternal moment of inertia from a speed of 3000 rpm without the brake being subject to an inadmissible amount of wear.
3)
This lifetime is only for reference. When a motor keeps running at 80% rated value and the surrounding temperature is
30 °C, the encoder lifetime can be ensured.

Other manuals for Siemens SIMOTICS S-1FL6

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMOTICS S-1FL6 and is the answer not in the manual?

Siemens SIMOTICS S-1FL6 Specifications

General IconGeneral
BrandSiemens
ModelSIMOTICS S-1FL6
CategoryServo Drives
LanguageEnglish

Related product manuals