Parameter list 01.04
11-152 SIEMENS AG 6SG7000-0BA76
SIMOTRAS HD Operating Instructions
PNU Description Value range
[Unit]
No. indices See
Change
n810
(2810)
(G195)
Diagnostic information for the paralleling interface [SW 2.1 and later]
3210
4
5
6
7
89101112131415
Paralleling master: (i.e. when U800 = 1)
Segment
0 ........
1 ........
2 ........ ON: Slave with address 2 responding
3 ........ ON: Slave with address 3 responding
4 ........ ON: Slave with address 4 responding
5 ........ ON: Slave with address 5 responding
6 ........ ON: Slave with address 6 responding
7 ........
8 ........ OFF
9 ........ OFF
10 ........
11 ........
12 ........
13 ........
14 ........
15 ........ ON: Master function active
Paralleling slave: (i.e. when U800 = 2)
Segment
0 ........
1 ........
2 ........ ON: Data for slave with address 2 are ok
3 ........ ON: Data for slave with address 3 are ok
4 ........ ON: Data for slave with address 4 are ok
5 ........ ON: Data for slave with address 5 are ok
6 ........ ON: Data for slave with address 6 are ok
7 ........
8 ........ ON: Slave function active
9 ........ ON: Firing pulses of master are used
10 ........
11 ........
12 ........
13 ........
14 ........
15 ........ OFF
Ind: None