01.04 Connectors and binectors
SIEMENS AG 6SG7000-0BA76 12-5
SIMOTRAS HD Operating Instructions
Connector Description Normalization Function
diag., Sheet
K0178
Band-stop output 2
16384
=
∧
100%
G152
K0179
Filtering element output for nact filtering
16384
=
∧
100%
G152
K0181
Lowest positive setpoint limit
16384
=
∧
100%
G137
K0182
Highest negative setpoint limit
16384
=
∧
100%
G137
K0183
Speed setpoint before limitation
16384
=
∧
100%
G137
K0190
Ramp-function generator output (before speed setpoint limitation)
16384
=
∧
100%
G136
K0191
dv/dt (rise in ramp-function generator output in time period set in P542)
16384
=
∧
100%
G136
K0192
Effective ramp-function generator input variable
16384
=
∧
100%
G136
K0193
Setpoint input for ramp-function generator
16384
=
∧
100%
G135
K0194
Total of main setpoint (limited) + additional setpoint
16384
=
∧
100%
G135
K0195
Ramp-function generator input before setpoint reduction
16384
=
∧
100%
G135
K0196
Effective positive limit for main setpoint
16384
=
∧
100%
G135
K0197
Effective negative limit for main setpoint
16384
=
∧
100%
G135
K0198
Main setpoint before limitation
16384
=
∧
100%
G135
Crawling setpoint, inching setpoint, oscillation, fixed setpoint
K0201
Crawling setpoint
16384
=
∧
100%
G130
K0202
Inching setpoint
16384
=
∧
100%
G129
K0203
Oscillation setpoint
16384
=
∧
100%
G128
K0204
Fixed setpoint
16384
=
∧
100%
G127
K0206
Crawling setpoint: Output value of function block
16384
=
∧
100%
G130
K0207
Inching setpoint: Output value of function block
16384
=
∧
100%
G129
K0208
Oscillation/square wave generator: Output value of function block
16384
=
∧
100%
G128
K0209
Fixed setpoint: Output value of function block
16384
=
∧
100%
G127
Connector selector switches
K0230
Output of connector selector switch 1 [SW 1.9 and later]
1
=
∧
1
G124
K0231
Output of connector selector switch 2 [SW 1.9 and later]
1
=
∧
1
G124
Motorized potentiometer
K0240
Motorized potentiometer output (setpoint from potentiometer)
16384
=
∧
100%
G126
K0241
dy/dt (rise in ramp-function generator output in time period set in P542 +
P465)
16384
=
∧
100%
G126
K0242
Ramp-function generator input in motorized potentiometer (setpoint)
16384
=
∧
100%
G126
General connectors
K0301
Line voltage U-V
16384
=
∧
P078.001
K0302
Line voltage V-W
16384
=
∧
P078.001
K0303
Line voltage W-U
16384
=
∧
P078.001
K0305
Average line voltage, filtered
16384
=
∧
P078.001
K0306
Line frequency
16384
=
∧
50.0Hz
K0309
Calculated motor temperature rise
Normalization:
16384
=
∧
the overtemperature which is reached at a
continuous current corresponding to the rated motor current
see Column 2
K0310
Calculated thyristor temperature rise as % of maximum permissible thyristor
temperature rise
16384
=
∧
100%
K0311
Hours run [SW 1.9 and later]
1
=
∧
1h
G189