01.04 Connections
SIEMENS AG 6SG7000-0BA76 6-37
SIMOTRAS HD Operating Instructions
Control inputs (see also Section 6.1 and Section 8, Sheets G117 and G118)
Function Terminal
X1
LED
Connection values/Remarks
LS - Control voltage connection
Common connection for control inputs
71 230V AC / 8 mA
Control input
In the factory setting, the parameter is
wired as the input for “Travel command 1
”
– FK1 for crane control
72 H72 230V AC / 8 mA
Control input
In the factory setting, the parameter is
wired as the input for “Travel command 2
”
– FK2 for crane control
73 H73 230V AC / 8 mA
Control input
In the factory setting, the parameter is
wired as the input for Notch
)
74 H74 230V AC / 8 mA
Control input
In the factory setting, the parameter is
wired as the input for “Pre-limit switch 1
” –
VE1
75 H75 230V AC / 8 mA
Control input
In the factory setting, the parameter is
wired as the input for “Pre-limit switch 2
” –
VE2
76 H76 230V AC / 8 mA
Control input
In the factory setting, the parameter is
wired as the input for “Limit switch 1
” –
LS1
77 H77 230V AC / 8 mA
Control input
In the factory setting, the parameter is
wired as the input for “Limit switch 2
” –
LS2
78 H78 230V AC / 8 mA
Control input
In the factory setting, the parameter is
wired as the input for the Acknowledge
key)
79 H79 230V AC / 8 mA