Connections 01.04
6-38 SIEMENS AG 6SG7000-0BA76
SIMOTRAS HD Operating Instructions
Control outputs (electrically isolated relay outputs)
(see also Section 8, Sheets G112 and G119)
Function Terminal
X2_4
LED
Connection values/Remarks
Control output
In the factory setting, the parameter is
wired as the output “No fault
”
109
110
H109
Control output
In the factory setting, the parameter is
wired as the output “No fault
”
81
82
H81
Load capability:
=250V AC, 4A; cosΦ=1
=250V AC, 2A; cosΦ=0,4
=30V DC, 2A
Function Terminal
X2_3
LED
Connection values/Remarks
Control output
In the factory setting, the parameter is
wired as the output “Acknowledgement
”
83
84
H83
Control output
In the factory setting, the parameter is
wired as the output “Brake contactor
”
85
86
H85
Load capability:
=250V AC, 4A; cosΦ=1
=250V AC, 2A; cosΦ=0,4
=30V DC, 2A
Function Terminal
X2_2
LED
Connection values/Remarks
S1 - "Rotor contactor stage 1"
Relay signal
"Switch rotor contactor S1"
87
88
H87
S2 - "Rotor contactor stage 2"
Relay signal
"Switch rotor contactor S2"
89
90
H89
Load capability:
=250V AC, 4A; cosΦ=1
=250V AC, 2A; cosΦ=0,4
=30V DC, 2A
Function Terminal
X2_1
LED
Connection values/Remarks
S3 - "Rotor contactor stage 3"
Relay signal
"Switch rotor contactor S3"
91
92
H91
S4 - "Rotor contactor stage 4"
Relay signal
"Switch rotor contactor S4"
93
94
H93
Load capability:
=250V AC, 4A; cosΦ=1
=250V AC, 2A; cosΦ=0,4
=30V DC, 2A