Connections 01.04
6-38 SIEMENS AG 6SG7000-0BA76
SIMOTRAS HD Operating Instructions
Control outputs (electrically isolated relay outputs)
(see also Section 8, Sheets G112 and G119)
Function Terminal
X2_4
LED
Connection values/Remarks
Control output
In the factory setting, the parameter is
wired as the output “No fault
109
110
H109
Control output
In the factory setting, the parameter is
wired as the output “No fault
81
82
H81
Load capability:
=250V AC, 4A; cosΦ=1
=250V AC, 2A; cosΦ=0,4
=30V DC, 2A
Function Terminal
X2_3
LED
Connection values/Remarks
Control output
In the factory setting, the parameter is
wired as the output “Acknowledgement
83
84
H83
Control output
In the factory setting, the parameter is
wired as the output “Brake contactor
85
86
H85
Load capability:
=250V AC, 4A; cosΦ=1
=250V AC, 2A; cosΦ=0,4
=30V DC, 2A
Function Terminal
X2_2
LED
Connection values/Remarks
S1 - "Rotor contactor stage 1"
Relay signal
"Switch rotor contactor S1"
87
88
H87
S2 - "Rotor contactor stage 2"
Relay signal
"Switch rotor contactor S2"
89
90
H89
Load capability:
=250V AC, 4A; cosΦ=1
=250V AC, 2A; cosΦ=0,4
=30V DC, 2A
Function Terminal
X2_1
LED
Connection values/Remarks
S3 - "Rotor contactor stage 3"
Relay signal
"Switch rotor contactor S3"
91
92
H91
S4 - "Rotor contactor stage 4"
Relay signal
"Switch rotor contactor S4"
93
94
H93
Load capability:
=250V AC, 4A; cosΦ=1
=250V AC, 2A; cosΦ=0,4
=30V DC, 2A

Table of Contents