After the OFF2 command
0RWRULVPDJQHWL]HG
6ZLWFKRQPRWRU
2SHUDWLRQHQDEOHG
2SHQEUDNH
%UDNHLVRSHQ
6SHHGVHWSRLQWU
21
2))
U 
U 
U 
S
S
W
W
W
W
W
W
00
Figure 6-22 Controlling the motor holding brake after OFF2
After the OFF2 command, the inverter issues the signal to immediately close the motor holding
brake, irrespective of the motor speed.
Commissioning a motor holding brake
WARNING
Load can fall if the "Motor holding brake" function is incorrectly set
For applications with a suspended load, such as cranes and elevators, there is a danger to
life if the "Motor holding brake" function is not completely set or is incorrectly set.
When commissioning the "Motor holding brake" function, secure any suspended loads,
e.g. by applying the following measures:
Lower the load down to the floor.
Secure the dangerous area so that nobody can inadvertently enter it.
Set the "Motor holding brake" function according to the following description.
After commissioning, check that the motor holding brake and the motor control function
reliably.
For applications involving suspended loads, we recommend that you use vector control
together with an encoder.
Requirements
The motor holding brake is connected to the inverter.
You have assigned the "Controlling the motor holding brake" function to a digital output:
DO 0: p0730 = 52.12
DO 1: p0731 = 52.12
Advanced commissioning
6.12 Motor holding brake
SINAMICS G120C converter
Operating Instructions, 09/2017, FW V4.7 SP9, A5E34263257B AF 207