EasyManua.ls Logo

Siemens SINAMICS G120C USS/MB - Replacing the Roof-Mounted Fan

Siemens SINAMICS G120C USS/MB
470 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
9.2.8 Replacing the roof-mounted fan
Inverters, frame sizes FSAA FSC have a roof-mounted fan. The roof-mounted fan is located
at the upper side of the inverter.
When must the roof-mounted fan be replaced?
A defective roof-mounted fan in operation results in an overtemperature condition of the
inverter. For example, the following messages indicate that a roof-mounted fan is defective:
A30034 (overtemperature inside the enclosure)
F30036 (overtemperature, inside area)
A30049 (defective fan inside the enclosure)
F30059 (defective fan inside the enclosure)
5HPRYHIDQ,QVHUWIDQ
Figure 9-2 Removing and installing the interior fan
Removing the roof-mounted fan
Procedure
Proceed as follows to remove the roof-mounted fan:
1. Switch off the inverter power supply.
WARNING
Electric shock as a result of a residual charge in power components
After the power supply has been switched off, it takes up to 5 min. until the capacitors in
the inverter have discharged so that the residual charge is at a non-hazardous level.
Check the voltage at the inverter connections before you carry out any installation work.
2. Using a screwdriver, press the locking lugs of the roof-mounted fan together.
3. Withdraw the roof-mounted fan from the inverter.


Corrective maintenance
9.2 Replacing inverter components
SINAMICS G120C converter
Operating Instructions, 09/2017, FW V4.7 SP9, A5E34263257B AF 389