6.13 Free function blocks
The free function blocks permit configurable signal processing in the inverter.
The following free function blocks are available:
AND, OR, XOR, and NOT logic
RSR (RS flip-flop), DSR (D flip-flop) flip-flops
Timers MFP (pulse generator), PCL (pulse shortening), PDE (ON delay), PDF (OFF delay),
and PST (pulse stretching)
ADD (adder), SUB (subtractor), MUL (multiplier), DIV (divider), AVA (absolute value
generated), NCM (comparator), and PLI (polyline) arithmetic functions
LIM (limiter), PT1 (smoothing), INT (integrator), DIF (differentiator) controllers
NSW (analog) BSW (binary) switches
LVM limit value monitoring
The number of free function blocks in the inverter is limited. You can only use a function block
once. The inverter has 3 adders, for instance. If you have already configured three adders,
then no other adders are available.
Application description for the free function blocks
Further information is provided in the Internet:
FAQ (http://support.automation.siemens.com/WW/view/en/85168215)
Advanced commissioning
6.13 Free function blocks
SINAMICS G120C converter
210 Operating Instructions, 09/2017, FW V4.7 SP9, A5E34263257B AF