r2123 Alarm time received in milliseconds
Displays the time in milliseconds when the alarm occurred
r2124 Alarm value
Displays additional information about the alarm
r2125 Alarm time removed in milliseconds
Displays the time in milliseconds when the alarm was removed
r2132 Actual alarm code
Displays the code of the alarm that last occurred
r2134 Alarm value for float values
Displays additional information about the alarm that occurred for float values
Extended settings for alarms
Table 8-7 Extended settings for alarms
Parameter Description
You can change up to 20 different alarms into a fault or suppress alarms:
p2118 Setting the message number for the message type
Select the alarms for which the message type should be changed
p2119 Setting the message type
Setting the message type for the selected alarm
1: Fault
2: Alarm
3: No message
You will find details in function diagram 8075 and in the parameter description of the List
Manual.