Inverter Line reactor Line reactor as base
component
Frame size B 5.5 kW … 7.5 kW 6SL3210‑1KE21‑3 . . 1
6SL3210‑1KE21‑7 . . 1
6SL3203‑0CE21‑8AA0 ---
Frame size C 11.0 kW … 18.5 kW 6SL3210‑1KE22‑6 . . 1
6SL3210‑1KE23‑2 . . 1
6SL3210‑1KE23‑8 . . 1
6SL3203‑0CE23‑8AA0 ---
Frame size
D … frame size F
22 kW … 132 kW An external line reactor is not required.
1)
with restrictions for G120C FSAA, 2.2 kW. See below.
Sine-wave filter
Sine-wave filters limit the the rate of voltage rise (dv/dt) and the peak voltages at the motor
winding. The sine-wave filter increases the maximum permissible length of the motor cables.
Inverter Sine-wave filter Sine-wave filter as base
component
Frame size AA 0.55 kW … 2.2 kW 6SL3210‑1KE11‑8U . 2
6SL3210‑1KE12‑3U . 2
6SL3210‑1KE13‑2U . 2
6SL3210‑1KE14‑3U . 2
6SL3210‑1KE15‑8U . 2
1)
--- 6SE6400‑3TD00‑4AD0
Frame size A … frame size F (3 kW … 132 kW): A sine-wave filter is not available.
1)
with restrictions, see below.
Output reactor
In order to increase the maximum permissible motor cable length you need one or two output
reactors, depending on the inverter.
● Frame size AA … frame size C: An output reactor
● Frame size D … frame size F: Two output reactors connected in series
Inverter Output reactor Output reactor as base
component
Frame size AA 0.55 kW … 2.2 kW 6SL3210‑1KE11‑8 . . .
6SL3210‑1KE12‑3 . . .
6SL3210‑1KE13‑2 . . .
6SL3210‑1KE14‑3 . . .
6SL3210‑1KE15‑8 . . .
6SL3202‑0AE16‑1CA0 6SE6400‑3TC00‑4AD2
1)
Frame size A 3.0 kW … 4.0 kW 6SL3210‑1KE17‑5 . . 1
6SL3210‑1KE18‑8 . . 1
6SL3202‑0AE18‑8CA0 ---
Frame size B 5.5 kW … 7.5 kW 6SL3210‑1KE21‑3 . . 1
6SL3210‑1KE21‑7 . . 1
6SL3202‑0AE21‑8CA0 ---
Frame size C 11.0 kW … 18.5 kW 6SL3210‑1KE22‑6 . . 1
6SL3210‑1KE23‑2 . . 1
6SL3210‑1KE23‑8 . . 1
6SL3202‑0AE23‑8CA0 ---
Description
3.4 Optional components
SINAMICS G120C converter
Operating Instructions, 09/2017, FW V4.7 SP9, A5E34263257B AF 37