Connecting the line supply and motor, frame size FSF
Figure 4-23 Connecting the line supply and motor, FSF
Remove the lower connection covers.
Use side cutters or a fine saw blade to make openings in the cover for the cables.
You must re-attach the covers in order to re-establish the touch protection of the inverter after
the cables have been connected.
Connecting the braking resistor, frame sizes FSD … FSF
We recommend mounting the shield plate. The shield plate is not included in the scope of
delivery of the inverter.
Spare parts (Page 383)
Procedure
To connect a braking resistor, proceed as follows:
1. Remove the upper inverter cover.
2. Release the two braking resistor terminals.
3. Remove the seal together with the connection cover upwards away from the inverter.
Installing
4.8 Connect the line supply, motor and braking resistor
SINAMICS G120C converter
72 Operating Instructions, 09/2017, FW V4.7 SP9, A5E34263257B AF