Setpoint Channel and Closed-Loop Control 11/03
SINAMICS G150
7-8 Operating Manual
Setting Parameters for Suppression Speeds
Setting range: 0.000 ... 210000.000 1/min
p1091 Suppression speed 1
Factory setting: 0.000 1/min
Setting parameter for suppression speed 1.
Setting range: 0.000 ... 210000.000 1/min
p1092 Suppression speed 2
Factory setting: 0.000 1/min
Setting parameter for suppression speed 2.
Setting range: 0.000 ... 210000.000 1/min
p1093 Suppression speed 3
Factory setting: 0.000 1/min
Setting parameter for suppression speed 3.
Setting range: 0.000 ... 210000.000 1/min
p1094 Suppression speed 4
Factory setting: 0.000 1/min
Setting parameter for suppression speed 4.
Setting range: 0.000 ... +210000.000 1/min
p1101 Suppression speed bandwidth
Factory setting: 0.000 1/min
Setting for the bandwidth for suppression speeds 1 to 4.
7.3 Closed-Loop Control
(in preparation)