Diagnosis / Faults and Alarms 11/03
SINAMICS G150
10-6 Operating Manual
r4022 Status of TM31 digital inputs
Display of the digital input status.
Bit 00: DI 0 (X520.1) 0: OFF 1: ON
Bit 01: DI 1 (X520.2) 0: OFF 1: ON
Bit 02: DI 2 (X520.3) 0: OFF 1: ON
Bit 03: DI 3 (X520.4) 0: OFF 1: ON
Bit 04: DI 4 (X530.1) 0: OFF 1: ON
Bit 05: DI 5 (X530.2) 0: OFF 1: ON
Bit 06: DI 6 (X530.3) 0: OFF 1: ON
Bit 07: DI 7 (X530.4) 0: OFF 1: ON
Bit 08: DI/DO 8 (X541.2) 0: OFF 1: ON
Bit 09: DI/DO 9 (X541.3) 0: OFF 1: ON
Bit 10: DI/DO 10 (X541.4) 0: OFF 1: ON
Bit 11: DI/DO 11 (X541.5) 0: OFF 1: ON
r4047
Status of TM31 digital outputs
Display of the TM31 digital output status.
Bit 00: DO 0 (X542.1-3) 0: OFF 1: ON
Bit 01: DO 1 (X542.4-6) 0: OFF 1: ON
Bit 08: DO 8 (X541.2) 0: OFF 1: ON
Bit 09: DO 9 (X541.3) 0: OFF 1: ON
Bit 10: DO 10 (X541.4) 0: OFF 1: ON
Bit 11: DO 11 (X541.5) 0: OFF 1: ON