Loading...
Installing
3.4 Mounting the Power Modules
Power Module PM240-2
Hardware Installation Manual, 01/2020, A5E33294624B AL
39
Procedure - FSD and FSE
Proceed as follows to mount the EMC connecting bracket and the shield plate:
1. Attach the EMC connecting bracket to the shield plate
.
2. Then slide the shield module into the converter, so that it is held in the converter
by
the clamping spring. The shield module is located correctly if it can be easily withdrawn
out of the converter without any resistance.
3. After you have ensured that it is correctly located, fix the shield module using the four
screws
.
You have correctly mounted the EMC connecting bracket and the shield plate.
Procedure - FSF:
Proceed as follows to mount the EMC connecting bracket and the shield plate:
1. Attach the EMC connecting bracket to the shield plate
.
2. Screw the shield module to the converter
using three screws, as shown in the
diagram.
You have correctly mounted the EMC connecting bracket and the shield plate.