(or alarms 200000ff etc. created from these in the HMI)
as well as drive safety alarms 27900.
Meaning of the MD values:
0 = alarms/warnings are evaluated immediately
1 = alarms/warnings are not evaluated
2 = alarms are evaluated only after power up, i.e.
as soon as HMI has set value 2 active again (NCK automatically
resets the MD value to 1 at every power up; HMI must
explicitely articulate its readiness for message processing
by setting value 2)
Note: the MD restricts the range or effectiveness
of MD13150 $MN_SINAMICS_ALARM_MASK
Default: the display default behavior of the mentioned drive
alarms changes with the introduction of this MD.
Now the alarms are not transported and displayed
by default.
The previous default behavior can be restored
with MD13140 $MN_PROFIBUS_ALARM_ACCESS=0.
13150 SINAMICS_ALARM_MASK N04, N05 -
- Activate fault and warning buffer output for Sinamics DWORD Immediately
-
808d-me42 - 0x0 0 0x7FFFFFFF ReadOnly M
808d-me62 - 0x0 0 0x7FFFFFFF ReadOnly M
808d-te42 - 0x0 0 0x7FFFFFFF ReadOnly M
808d-te62 - 0x0 0 0x7FFFFFFF ReadOnly M
808d-mte40 - 0x0 0 0x7FFFFFFF 7/2 M
808d-mte60 - 0x0 0 0x7FFFFFFF 7/2 M
Description: For PROFIBUS/PROFINET only, especially SINAMICS:
Relevant to SINAMICS diagnostics:
Note: the effect of this MD may be hidden independently of
the value of MD13140 $MN_PROFIBUS_ALARM_ACCESS.
Mask for displaying the SINAMICS DOS fault and warning buffers
Bit set: Alarms in this DO group are output
Bit not set: Alarms in this DO group are not output
Bit Hex. Meaning
value
====================================================================================
0: 0x1 Output faults of the Control Units
1: 0x2 Reserved
2: 0x4 Output faults of the Drive Controls
3: 0x8 Output faults of the Line Modules
4: 0x10 Output faults of the Terminal Boards
5: 0x20 Output faults of the Terminal Modules
8: 0x100 Output warnings of the Control Units
9: 0x200 Output warnings of the Communication Objects
10: 0x400 Output warnings of the Drive Controls
11: 0x800 Output warnings of the Line Modules
12: 0x1000 Ouptut warnings of the Terminal Boards
Machine data
3.2 General machine data
Parameter Manual
List Manual, 01/2017 83

Table of Contents

Other manuals for Siemens SINUMERIK 808D