8
Alarms and Messages 10.04
8.2 Alarms in Sho
p
Mill
8
ï›™ Siemens AG, 2004. All rights reserved
8-412 SINUMERIK 840D/840Di/810D Operation/Programming ShopMill (BAS) – 10.04 Edition
112502
Not enough memory
Program aborted in line %1
Explanation %1 = Line number
Program contains too many program blocks
Response Alarm display
Program not loaded
Remedy Modify program in operating area PROGRAMS CNC-ISO operator
interface.
112503
ShopMill XXXX
Explanation A system error has occurred.
Response Alarm display
Remedy Please note the error text and contact the Siemens A&D MC Hotline.
112504
File does not exist or is incorrect: %1
Explanation %1 = Name of file/contour
Program cannot interpret a program block with contour programming.
Contour does not exist in directory.
Response Alarm display
NC Start disable
Remedy Load contour in directory.
112505
Error while trying to interpret contour %1
Explanation %1 = Name of contour
Contour incorrect
Response Alarm display
NC Start disable
Remedy Check machining sequence of contour
112506
Maximum number of contour elements exceeded %1
Explanation %1 = Name of contour
Max. permissible number of 50 contour elements exceeded during
interpretation of machining sequence of a contour.
Response Alarm display
Remedy Check machining sequence of contour and change if necessary.
112541
Program cannot be interpreted
Explanation The program cannot be interpreted as a sequential control program
during loading, as the program header is missing.
Response Alarm display
NC Start disable
Remedy -