9.1.4 Connection
Power supply X124
Table 9-2 Pin assignment for X124
Pin Function
+ 24 V DC power supply (20.4 V - 28.8 V)
+
M Ground
M
Note
The two "+" and "M" terminals are jumpered in the connector and not in the device. This ensures
that the supply voltage is looped through.
The current consumption increases by the current consumption of DRIVE-CLiQ and the digital
outputs.
When using external power supplies (e.g. SITOP), the ground potential must be connected with
the protective ground terminal (PELV).
Table 9-3 Cable speci󹪝cation for X124
Features Version
Connector type 4-pin screw terminal
Connectable cable types and conductor cross-sections
Rigid
Flexible
Flexible, with end sleeve without plastic sleeve
Flexible, with end sleeve with plastic sleeve
AWG / kcmil
0.2 mm² to 2.5 mm²
0.2 mm² to 2.5 mm²
0.2 mm² to 2.5 mm²
0.2 mm² to 1.5 mm²
22 to 12
Stripped length 6-7 mm
Tool Screwdriver 0.5 x 3 mm (M2.5)
Tightening torque 0.4 to 0.5 Nm
Max. current carrying capacity, incl. loop-through 20 A (15 A according to UL/CSA)
Max. cable length 10 m
Connectable components
9.1 NX10.3 / NX15.3
NCU 7x0.3B PN
94 Equipment Manual, 10/2020, 6FC5397-1EP40-6BA1