12/2008 3 Setting up functions
3.4 Fault services
© Siemens AG 2008 All Rights Reserved
ePS Network Services, Function Manual (FH) - Release 12/2008
3-105
3.4.2 Control monitors – Detailed view
Description of functions
The detailed view of a control monitor is accessed by selecting an existing control
monitor or creating a new one.
Fig. 3-19: Configuring a control monitor
Control monitors are divided into three modules:
1. Trigger module
2. Action module
3. Workflow module
The function settings for a control monitor are made in the general part.
The triggers are used to configure the logic which links information queries
from the NC, PLC or database; in order to initiate actions and/or workflows.
Workflows are notifications via e-mail or SMS and maintenance schedules.
Diagnostic actions are data acquired from the control (NCK, PLC, PC).
Actions
After you have created a new control monitor or opened a control monitor for
editing, you can perform the following actions:
Select or change the trigger signals that will cause the monitor to run.
Define or change the actions to be executed when a trigger is detected.

Table of Contents