12/2008 3 Setting up functions
3.2 Configuring measurements and measurement series
© Siemens AG 2008 All Rights Reserved
ePS Network Services, Function Manual (FH) - Release 12/2008
3-95
Configuring the limit values
With the equability test, one movement is carried out each forwards and
backwards. The characteristics are calculated separately for each direction. As
standard limit values are defined for the characteristics and are the same for both
directions of movement.
Optionally limit values can be entered which can have different values for both
directions for each characteristic.
Fig. 3-11: Measurement series of a equability test on the PC
3.2.3 Universal axis test
Parameter description
Parameters for conducting a universal axis test:
Field Content Type
Name Name of the measurement series
(measurements do not have a name)
INPUT
Channel Selection of the required channel: The
channel defines the possible machine axes
in the "Axis" selection list.
SELECTION
Axis Selection from the possible machine axes
that can be programmed in the selected
channel
SELECTION
Start point The axis position at which the various
movements of the measurement begin.
The position value is never lower than this
value during measurement.
INPUT